Additional information
SKU | VPL12N |
---|---|
Brand | Schneider |
Categories | Capacitor |
Weight | 0.732 kg |
Dimensions | 18.4 × 17.7 × 9.2 cm |
Warna | |
Datasheet PDF | www.se.com/id/id/product/download-pdf/VPL12N |
Rp14.886.300 Rp9.824.900 34% off! Sale!
Regulator Kapasitor 12 Step Schneider Varplus Logic 12- PF regulator 12 step
Main
Range
PowerLogic
product name
PowerLogic PFC Controller
Device short name
VPL12
Product or component type
Power factor controller
Complementary
number of step output contacts
12
[Us] rated supply voltage
90…550 V AC
<= 999 kV AC with external VT
Measurement current
0…5 A
Measurement voltage
90…550 V AC 50/60 Hz
operating mode
Manual or automatic
number of quadrant operation for generator application
4
Device connection
Communication protocol: Modbus interface: RS485
Input function
Switch: 1 x dry contact
Colour code
Front: dark grey RAL 7016
Display type
Backlit LCD
Display size
56 x 25 mm
Function available
Manual programming
Automatic initialisation
Automatic detection
Advanced programming (expert)
Any step sequence
Metering typePower factor and displacement PF (signed, four quadrant)
Total current harmonic distortion THD (I)
Power factor average over lifetime
Temperature maximum
Phase current I1, I2, I3 RMS on load
Active power P, P1, P2, P3 on load
Reactive power Q, Q1, Q2, Q3 on load
Apparent power S, S1, S2, S3 on load
Voltage U21, U32, U13, V1, V2, V3 on load
type of measurement
Capacitor current overload Irms/I1
Individual voltage harmonic
Power factor
Operating time
Cos φ
Ambient temperature inside the cubicle
Tan φ
Information displayed
Number of switching cycles per step
Individual step size in kVAr
Remaining step capacity in %
Type of alarms
Step power loss (< 75 %) / Action: message and alarm contact + step blocked
Step faulty / Action: message and alarm contact + step blocked
High current (> 6 A CT) / Action: message and alarm contact
Hunting (unstable regulation) / Action: message and alarm contact + step blocked
Low current (< 15 mA CT) / Action: message and alarm contact
Overcompensation / Action: message and alarm contact
Capacitor current overload (Irms/I1) (> 130 % I1) / Action: message and alarm contact + step switched off
Overtemperature (50 °C) / Action: message and alarm contact + step switched off
Overtemperature (30 °C) / Action: fan switch
Overvoltage (+/- 10 %) / Action: message and alarm contact + control stopped
Total harmonic distortion (> 7 %) / Action: message and alarm contact + step switched off
Data recording
5 alarms
Operational Hours alarm
100000 h without maintenance
Operational counter alarm
65000 cycles without maintenance
Input type
Phase to phase
Phase to neutral
Insensitive to CT polarity
Insensitive to phase rotation polarity
Current input CT…X/5 A and X/1 A
Output type
Control relay: 0.2 A 110 V DC
Control relay: 1 A 48 V DC
Control relay: 2 A 400 V AC 50/60 Hz
Control relay: 1 A 24 V DC
Control relay: 5 A 250 V AC 50/60 Hz
Control relay: 5 A 120 V AC 50/60 Hz
Fan: 5 A 250 V AC 50/60 Hz
Fan: 1 A 48 V DC
Alarm relay: 5 A 250 V AC 50/60 Hz
Alarm relay: 1 A 48 V DC
Maximum at the common terminal
10 A
Settings operating mode
Automatic
Manual
Type of setting
Choice of stepping programs: auto
Choice of stepping programs: LIFO
Choice of stepping programs: linear
Delay between 2 successive switch on the same step: 5…1200 s
Step configuration programming: auto
Step configuration programming: off
Step configuration programming: fixed
Target cos phi: 0.7 inductive…0.7 capacitive
Target cos phi: dual cos φ
Measurement accuracy
Voltage +/- 1 %
Current +/- 1 %
Frequency +/- 1 %
Energy (P,Q,S) +/- 2 %
Cos φ +/- 2 %
Total voltage harmonic distortion THD (U) +/- 2 %
Individual voltage harmonic +/- 3 %
Temperature +/- 3 °C
Time delay range
1…6500 s (on reconnection)
1…6500 s (on response)
Provided equipment
User manual
Mounting mode
Flush-mounted
Mounting support
Panel – thickness: 1…3 mm
Regulator Kapasitor 12 Step Mounting location
In cabinet
Cut-out dimensions
138 x 138 mm
Height
144 mm
Width
144 mm
Depth
58 mm
Net weight
0.6 kg
Environment
Standards
IEC 61000-6-4
UL 61010-1
EN 61010-1
IEC 61000-6-2
IEC 61326-1
Product certifications
EAC
NRTL
cNRTL
CE
IP degree of protection
Front face: IP41
Rear face: IP20
Operating altitude
<= 2000 m
ambient air temperature for operation
-20…60 °C
Ambient air temperature for storage
-40…85 °C
Packing Units
Unit Type of Package 1
PCE
Number of Units in Package 1
1
Package 1 Height
9.2 cm
Package 1 Width
17.7 cm
Package 1 Length
18.4 cm
Package 1 Weight
724 g
Unit Type of Package 2
S03
Number of Units in Package 2
8
Package 2 Height
30 cm
Package 2 Width
30 cm
Package 2 Length
40 cm
Package 2 Weight
6.301 kg
Unit Type of Package 3
P06
Number of Units in Package 3
64
Package 3 Height
75 cm
Package 3 Width
60 cm
Package 3 Length
80 cm
Package 3 Weight
58.408 kg
Varplus Logic 12- PF regulator 12 step
Stock Available
SKU | VPL12N |
---|---|
Brand | Schneider |
Categories | Capacitor |
Weight | 0.732 kg |
Dimensions | 18.4 × 17.7 × 9.2 cm |
Warna | |
Datasheet PDF | www.se.com/id/id/product/download-pdf/VPL12N |
You must be logged in to post a review.
Most Complete Product Range
We have thousands of products in our shop to help fulfil your need.
Free Shipping & Return
We offer free shipping on selected cities in East Java, Terms & Condition apply.
Secure Database & Payment
Your information is transmitted in a very safe way.
Supportive Customer Service
Say hello to us at +6282223332830
Showroom
Jl. Jagalan No. 38 Surabaya, Jawa Timur
WA : +62 822 2888 2830
Head Quarter
Jl. Ruko Galaxi Block J-1 No. 23 Sukolilo, Semolowaru. Jawa Timur Surabaya
WA : +62 822 2333 2830
© 2019 – 2023 PT. Anugerah Tama Sejati
Reviews
There are no reviews yet.