Schneider VPL06N Regulator Capacitor 6 step Main Specification
- PowerLogic PFC Controller
- VPL6 device short name
- Power factor controller product type
- 6 step output contacts
- Rated supply voltage:
- 90…550 V AC
- <= 999 kV AC with external VT
- 0…5 A measurement current
- 90…550 V AC 50/60 Hz measurement voltage
- Manual or automatic operating mode
- 4 quadrant operation for generator application
- Communication protocol: Modbus interface: RS485 device connection
- Switch: 1 x dry contact input function
- Front: dark grey RAL 7016 colour code
- Backlit LCD display type
- 56 x 25 mm display size
Complementary
- Function available:
- Automatic detection
- Advanced programming (expert)
- Manual programming
- Any step sequence
- Automatic initialisation
- Metering type:
- Power factor and displacement PF (signed, four quadrant)
- Total current harmonic distortion THD (I)
- Power factor average over lifetime
- Temperature maximum
- Phase current I1, I2, I3 RMS on load
- Active power P, P1, P2, P3 on load
- Reactive power Q, Q1, Q2, Q3 on load
- Apparent power S, S1, S2, S3 on load
- Voltage U21, U32, U13, V1, V2, V3 on load
- Type of measurement:
- Ambient temperature inside the cubicle
- Tan φ
- Individual voltage harmonic
- Cos φ
- Operating time
- Power factor
- Capacitor current overload Irms/I1
- Information displayed:
- Number of switching cycles per step
- Remaining step capacity in %
- Individual step size in kVAr
- Type of alarms:
- Step power loss (< 75 %) / Action: message and alarm contact + step blocked
- Step faulty / Action: message and alarm contact + step blocked
- High current (> 6 A CT) / Action: message and alarm contact
- Hunting (unstable regulation) / Action: message and alarm contact + step blocked
- Low current (< 15 mA CT) / Action: message and alarm contact
- Overcompensation / Action: message and alarm contact
- Capacitor current overload (Irms/I1) (> 130 % I1) / Action: message and alarm contact + step switched off
- Overtemperature (50 °C) / Action: message and alarm contact + step switched off
- Overtemperature (30 °C) / Action: fan switch
- Overvoltage (+/- 10 %) / Action: message and alarm contact + control stopped
- Total harmonic distortion (> 7 %) / Action: message and alarm contact + step switched off
Environment
- 5 alarms data recording
- 100000 Hours alarm without maintenance
- 65000 cycles Operational counter alarm without maintenance
- Input type:
- Insensitive to phase rotation polarity
- Insensitive to CT polarity
- Phase to neutral
- Current input CT…X/5 A and X/1 A
- Phase to phase
- Output type:
- Control relay:
- 0.2 A 110 V DC
- 1 A 48 V DC
- 2 A 400 V AC 50/60 Hz
- 1 A 24 V DC
- 5 A 250 V AC 50/60 Hz
- 5 A 120 V AC 50/60 Hz
- Fan: 5 A 250 V AC 50/60 Hz
- Fan: 1 A 48 V DC
- Alarm relay: 5 A 250 V AC 50/60 Hz
- Alarm relay: 1 A 48 V DC
- 10 A Maximum at the common terminal
- Manual & Automatic Settings operating mode
- Type of setting:
- Choice of stepping programs: auto, LIFO, linear
- Delay between 2 successive switch on the same step: 5…1200 s
- Step configuration programming: auto, off, fixed
- Target cos phi: 0.7 inductive…0.7 capacitive
- Target cos phi: dual cos φ
- Measurement accuracy:
- Voltage +/- 1 %
- Current +/- 1 %
- Frequency +/- 1 %
- Energy (P,Q,S) +/- 2 %
- Cos φ +/- 2 %
- Total voltage harmonic distortion THD (U) +/- 2 %
- Individual voltage harmonic +/- 3 %
- Temperature +/- 3 °C
- Time delay range:
- 1…6500 s (on reconnection)
- 1…6500 s (on response)