Schneider GV3L25 Thermal Magnetic Motor Circuit Breaker 25 A 11 KW - GV3L25
Rp2.505.300 Rp1.327.800 47% off! Sale!
Schneider GV3L25 Thermal Magnetic Motor Circuit Breaker 25 A 11 KW
Schneider GV3L25 Thermal Magnetic Motor Circuit Breaker Main Specification
- TeSys GV2 range of product
- GV2P device short name
- Product name:
- Motor circuit breaker product type
- Motor protection device application
- Thermal-magnetic trip unit technology
- 3 Poles
- AC network type
- Utilisation Category A conforming to IEC 60947-2
- 50/60 Hz network frequency conforming to IEC 60947-4-1
- Fixing mode:
- 35 mm symmetrical DIN rail: clipped
- Panel: screwed (with 3 x M4 screws)
- Any operating position
Complementary
- Motor power kW:
- 11 kW at 400/415 V AC 50/60 Hz
- 15 kW at 500 V AC 50/60 Hz
- 18.5 kW at 690 V AC 50/60 Hz
- Breaking capacity:
- 100 kA Icu at 230/240 V AC 50/60 Hz
- 100 kA Icu at 400/415 V AC 50/60 Hz
- 50 kA Icu at 440 V AC 50/60 Hz
- 12 kA Icu at 500 V AC 50/60 Hz
- 6 kA Icu at 690 V AC 50/60 Hz
- Rated service short-circuit breaking capacity:
- 100 % at 230/240 V AC 50/60 Hz
- 50 % at 690 V AC 50/60 Hz
- 100 % at 400/415 V AC 50/60 Hz
- 100 % at 440 V AC 50/60 Hz
- 50 % at 500 V AC 50/60 Hz
- Rotary handle control type
- 25Â A rated current
- 350Â A magnetic tripping current
- 690 V AC 50/60 Hz rated operational voltage conforming to IEC 60947-2
- 690 V AC 50/60 Hz rated insulation voltage conforming to IEC 60947-2
- 6 kV rated impulse withstand voltage conforming to IEC 60947-2
- 8Â W power dissipation per pole
- 100000 cycles mechanical durability
- 100000 cycles for AC-3 electrical durability at 415 V
Environment
- 25 cyc/h maximum operating rate
- Continuous rated duty conforming to IEC 60947-4-1
- Tightening torque:
- 5 N.m on EverLink BTR screw connectors for cable 25 mm²
- 8 N.m on EverLink BTR screw connectors for cable 35 mm²
- Mechanical robustness:
- Shocks: 15 Gn for 11 ms closed conforming to IEC 60068-2-27
- Shocks: 30 Gn for 11 ms opened conforming to IEC 60068-2-27
- Vibrations: 4 Gn, 5…300 Hz conforming to IEC 60068-2-6
- Phase failure sensitivity conforming to IEC 60947-4-1
- Suitability for isolation conforming to IEC 60947-1 § 7-1-6
- Standards:
- EN/IEC 60947-2
- EN/IEC 60947-4-1
- UL 60947-4-1
- CSA C22.2 No 60947-4-1
- Product certifications:
- CCC
- EAC
- BV
- LROS (Lloyds register of shipping)
- DNV-GL
- ABS
- UL
- CSA
- UKCA
- Climatic withstand Conforming to IACS E10
- IP20 conforming to IEC 60529
- -40…80 °C ambient air temperature for storage
- 960 °C fire resistance conforming to IEC 60695-2-11
- 3000 m operating altitude
- -20…60 °C ambient air temperature for operation