Schneider Control Relay CA3KN31BD 24 VDC 3 NO 1 NC
Rp650.500 Rp338.300 48% off!
Schneider Control Relay CA3KN31BD 24 VDC 3 NO + 1 NC
Schneider Control Relay CA3KN31BD Main Specification
- TeSys range
- TeSys CAK product name
- Control relay product type
- CA3K device short name
- Control circuit contactor application
- Utilisation category:
- 3 NO + 1 NC pole contact composition
- <= 690 V <= 400 Hz rated operational voltage
- DC standard control circuit type
- 24 V DC control circuit voltage
Complementary
- 10 A (at 50 °C) conventional free air thermal current
- 110 A Irms rated making capacity conforming to IEC 60947
- Associated fuse rating:
- 10 A gG conforming to IEC 60947
- 10 A gG conforming to VDE 0660
- Rated insulation voltage:
- 690 V conforming to IEC 60947
- 750 V conforming to VDE 0110 group C
- 690 V conforming to BS 5424
- 600 V conforming to CSA C22.2 No 14
- Rail & Plate mounting support
- Screw clamp terminals:
- 1 cable(s) 1.5…4 mm² solid
- 2 cable(s) 1.5…4 mm² solid
- 1 cable(s) 0.75…4 mm² flexible with cable end
- 2 cable(s) 0.75…4 mm²flexible without cable end
- 1 cable(s) 0.34…1.5 mm²flexible with cable end
- 2 cable(s) 0.34…1.5 mm²flexible without cable end
- Tightening torque:
- 1.3 N.m – on screw clamp terminals:
- Flat Ø 6 mm screwdriver
- Philips No 26 mm
- Pozidriv No 2
- Control circuit voltage limits:
- Operational: 0.8…1.15 Uc (at <50 °C)
- Drop-out: 0.1…0.75 Uc (at <50 °C)
- Operating time:
- 10 ms coil de-energisation and NO opening
- 30…40 ms coil energisation and NO closing
- 15 ms coil de-energisation and NC closing
- 25…35 ms coil energisation and NC opening
- 20 Mcycles mechanical durability
- 10000 cyc/h maximum operating rate
- 2 ms immunity to microbreaks
- 3 W (at 20 °C) inrush power in W
- 3 W at 20 °C hold-in power consumption in W
- 17 V minimum switching voltage
- 3 W heat dissipation
- 5 mA minimum switching current
- 0.5 mm non overlap distance
- > 10 MOhm insulation resistance
Environment
- Standards:
- BS 5424
- IEC 60947
- NF C 63-140
- VDE 0660
- Product certifications:
- IP2x from IP degree of protection
- TC protective treatment conforming to IEC 60068
- -25…50 °C ambient air temperature for operation
- -50…80 °C ambient air temperature for storage
- 2000 m without derating operating altitude
- Flame retardance:
- V1 conforming to UL 94
- Requirement 2 conforming to NF F 16-101
- Requirement 2 conforming to NF F 16-102
- Mechanical robustness:
- Vibrations contactor open: 2 Gn, 5…300 Hz conforming to IEC 60068-2-6
- Vibrations contactor closed: 4 Gn, 5…300 Hz conforming to IEC 60068-2-6
- Shocks contactor open: 10 Gn for 11 ms conforming to IEC 60068-2-27
- Shocks contactor closed: 15 Gn for 11 ms conforming to IEC 60068-2-27