Schneider XB4BT842 Emergency Stop Latching Push-pull 1NC - XB4BT842
Rp334.200 Sale!
Schneider XB4BT842 Emergency Stop XB4 22mm Latching Push-pull 1NC
Schneider XB4BT842 Emergency Stop Main Specification
- Harmony XB4 product range
- Product type:
- Emergency switching off push-button
- Emergency stop push-button
- XB4 short name
- Chromium plated metal bezel material
- Zamak fixing collar material
- 22 mm mounting diameter
- 1 sale per indivisible quantity
- Round shape for signaling unit head
- Trigger action and mechanical latching operator type
- Standard head type
- Push-pull for reset
- Red mushroom Ø 40 mm, unmarked operator profile
- Slow-break contact operation
- Connections – terminals:
- Screw clamp terminals, <= 2 x 1.5 mm² with cable end conforming to EN 60947-1
- Screw clamp terminals, >= 1 x 0.22 mm² without cable end conforming to EN 60947-1
Complementary
- (21-22)NC terminals description ISO n°1
- 7000000 Pa at 55 °C, distance : 0.1 m resistance to high pressure washer
- Standard contacts usage
- With positive opening conforming to EN/IEC 60947-5-1 appendix K
- Operating travel:
- 1.5 mm (NC changing electrical state)
- 4.3 mm (total travel)
- 300000 cycles mechanical durability
- 0.8…1.2 N.m tightening torque conforming to EN 60947-1
- Shape of screw head:
- Cross compatible with Philips no 1 screwdriver
- Cross compatible with pozidriv No 1 screwdriver
- Slotted compatible with flat Ø 4 mm screwdriver
- Slotted compatible with flat Ø 5.5 mm screwdriver
- Silver alloy (Ag/Ni) contacts material
- 10 A cartridge fuse type gG short-circuit protection conforming to EN/IEC 60947-5-1
- 10 A conventional free air thermal current conforming to EN/IEC 60947-5-1
- 600 V (pollution degree 3) rated insulation voltage conforming to EN 60947-1
- 6 kV ated impulse withstand voltage conforming to EN 60947-1
- Rated operational current:
- 3 A at 240 V, AC-15, A600 conforming to EN/IEC 60947-5-1
- 6 A at 120 V, AC-15, A600 conforming to EN/IEC 60947-5-1
- 0.1 A at 600 V, DC-13, Q600 conforming to EN/IEC 60947-5-1
- 0.27 A at 250 V, DC-13, Q600 conforming to EN/IEC 60947-5-1
- 0.55 A at 125 V, DC-13, Q600 conforming to EN/IEC 60947-5-1
- 1.2 A at 600 V, AC-15, A600 conforming to EN/IEC 60947-5-1
- Electrical durability:
- 1000000 cycles, AC-15, 2 A at 230 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C
- 1000000 cycles, AC-15, 3 A at 120 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C
- 1000000 cycles, AC-15, 4 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C
- 1000000 cycles, DC-13, 0.2 A at 110 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C
- 1000000 cycles, DC-13, 0.5 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C
- Electrical reliability:
- Λ < 10exp(-6) at 5 V and 1 mA in clean environment conforming to EN/IEC 60947-5-4
- Λ < 10exp(-8) at 17 V and 5 mA in clean environment conforming to EN/IEC 60947-5-4
- Complete product device presentation
Environment
- TH protective treatment
- -40…70 °C ambient air temperature for storage
- -40…70 °C ambient air temperature for operation
- Class I electrical shock protection conforming to IEC 60536
- IP degree of protection:
- IP66 conforming to IEC 60529
- IP67
- IP69
- IP69K
- Degree protection of NEMA:
- IK06 conforming to IEC 50102
- Standards:
- EN/IEC 60947-5-1
- UL 508
- CSA C22.2 No 14
- EN/ISO 13850
- EN/IEC 60947-5-5
- JIS C8201-5-1
- EN/IEC 60947-1
- EN/IEC 60947-5-4
- JIS C8201-1
- EN/IEC 60204-1
- IEC 60364-5-53
Emergency Stop XB4 22mm latching ?40 mm