Schneider MCB iC60N A9F74363 3P 63A 10kA - A9F74363
Rp1.528.500 Rp764.300 50% off! Sale!
Schneider MCB iC60N A9F74363 3P 63A 10kA. This Acti9 iC60N is a low voltage miniature circuit breaker (MCB). It is a 3P circuit breaker with 3 protected poles, 63A rated current and C tripping curve. The rated short circuit breaking capacity goes up to 20kA at 220VAC to 240VAC conforming to EN/IEC 60947-2 standard and 6000A at 400VAC conforming to EN/IEC 60898-1 standard. It complies with both industrial standard EN/IEC 60898-1 and residential standard EN/IEC 60947-2. This miniature circuit breaker protects circuits against short circuit and overload current. Its unique VisiTrip indicator reduces intervention time by showing the faulty circuit.
Schneider MCB iC60N A9F74363 3P 63A 10kA Main Specification
- Distribution Device application
- Acti9 Range
- Product name Acti9 iC60
- Product or component type Miniature circuit-breaker
- Device short name IC60N
- 3 Poles
- 3 protected poles
- [In] rated current 63 A
- Network type
- Trip unit technology Thermal-magnetic
- C Curve
- Breaking capacity
- 6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
- 36 kA Icu at 12…60 V AC 50/60 Hz conforming to EN/IEC 60947-2
- 10 kA Icu at 380…415 V AC 50/60 Hz conforming to EN/IEC 60947-2
- 20 kA Icu at 220…240 V AC 50/60 Hz conforming to EN/IEC 60947-2
- 6 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2
- 36 kA Icu at 100…133 V AC 50/60 Hz conforming to EN/IEC 60947-2
- 10 kA Icu at <= 180 V DC conforming to EN/IEC 60947-2
- Utilisation category A
- conforming to EN 60947-2
- conforming to IEC 60947-2
- Suitability for isolation conforming to
- EN 60898-1
- EN 60947-2
- IEC 60898-1
- IEC 60947-2
- Standards
- EN 60898-1
- EN 60947-2
- IEC 60898-1
- IEC 60947-2
Complementary
- Network frequency 50/60 Hz
- Magnetic tripping limit 8 x In +/- 20 %
- [Ics] rated service breaking capacity
- 15 kA 75 % conforming to EN 60947-2 – 220…240 V AC 50/60 Hz
- 7.5 kA 75 % conforming to EN 60947-2 – 380…415 V AC 50/60 Hz
- 4.5 kA 75 % conforming to EN 60947-2 – 440 V AC 50/60 Hz
- 15 kA 75 % conforming to IEC 60947-2 – 220…240 V AC 50/60 Hz
- 7.5 kA 75 % conforming to IEC 60947-2 – 380…415 V AC 50/60 Hz
- 4.5 kA 75 % conforming to IEC 60947-2 – 440 V AC 50/60 Hz
- 27 kA 75 % conforming to IEC 60947-2 – 12…133 V AC 50/60 Hz
- 27 kA 75 % conforming to EN 60947-2 – 12…133 V AC 50/60 Hz
- 6000 A 100 % conforming to EN 60898-1 – 400 V AC 50/60 Hz
- 6000 A 100 % conforming to IEC 60898-1 – 400 V AC 50/60 Hz
- 10 kA 100 % conforming to IEC 60947-2 – 125…180 V DC
- 10 kA 100 % conforming to EN 60947-2 – 125…180 V DC
- [Ui] rated insulation voltage
- 500 V AC 50/60 Hz conforming to EN 60947-2
- 500 V AC 50/60 Hz conforming to IEC 60947-2
- [Uimp] rated impulse withstand voltage
- 6 kV conforming to EN 60947-2
- 6 kV conforming to IEC 60947-2
- Contact position indicator
- Control type Toggle
- Local signalling Trip indicator
- Mounting mode Fixed
- Mounting support DIN rail
- Comb busbar and distribution block compatibility Top or bottom: YES
- 6 of 9 mm pitches
- Mechanical durability 20000 cycles
- Electrical durability 10000 cycles
- Connections – terminals
- Single terminal (top or bottom) 1…35 mm² rigid
- Single terminal (top or bottom) 1…25 mm² flexible
- Wire stripping length 14 mm for top or bottom connection
- Tightening torque 3.5 N.m top or bottom
- Separate block Earth-leakage protection
Environment
- IP degree of protection
- IP20 conforming to IEC 60529
- IP20 conforming to EN 60529
- Pollution degree
- 3 conforming to EN 60947-2
- 3 conforming to IEC 60947-2
- IV Overvoltage category
- Tropicalisation 2 conforming to IEC 60068-1
- Relative humidity 95 % at 55 °C
- Operating altitude 0…2000 m
- Ambient air temperature for operation -35…70 °C
- Ambient air temperature for storage -40…85 °C
Stock Available
Reviews
There are no reviews yet.