Schneider LV433834 NSX100F MCCB 4P 40A 36kA With Micrologic 4.2 - C10F44V040
Rp7.877.700 Sale!
Schneider LV433834 NSX100F MCCB 4P 40A 36kA With Micrologic 4.2
Schneider LV433834 NSX100F MCCB 4P 40A Main Specification
- 690 V AC 50/60 Hz rated operational voltage
- Suitability for isolation conforming to EN/IEC 60947-2
- Schneider LV433834 NSX100F MCCB 4P 40A rated ultimate short-circuit breaking capacity
- 85 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
- 36 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
- 35 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
- Micrologic 4.2 trip unit name
- Electronic trip unit technology
- LSoIR trip unit protection functions
- Toggle control type
- Fixed Circuit breaker mounting mode
Complementary
- 500 V AC 50/60 Hz rated insulation voltage
- 8 kV rated impulse withstand voltage
- Rated service short-circuit breaking capacity:
- 85 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
- 36 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
- 35 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
- 50000Â cycles mechanical durability
- Electrical durability:
- 30000 cycles at 440 V In
- 50000 cycles at 440 V In/2
- Backplate mounting support
- Front upside & downside connection
- 45 mm connection pitch
- Protection type:
- L : for overload protection (long time)
- So : for short time short-circuit protection with fixed delay
- I : for instantaneous short-circuit protection
- R : for earth-leakage protection
- Adjustable 9 settings Long-time pick-up adjustment type Ir (thermal protection)
- Long-time protection pick-up adjustment range from 18 to 40 A
- Fixed Long-time protection delay adjustment type tr
- Long-time protection delay adjustment range:
- 11 s at 7.2 x Ir
- 16 s at 6 x Ir
- 400 s at 1.5 x Ir
Environment
- Thermal memory 20 minutes before and after tripping
- Adjustable 9 settings Short-time protection pick-up adjustment type Isd
- 1.5…10 x Ir Short-time protection pick-up adjustment range
- Fixed Short-time protection delay adjustment type tsd
- 0.02 s Short-time protection delay adjustment range
- Fixed Instantaneous protection pick-up adjustment type Ii
- 600 A instantaneous protection pick-up adjustment range
- Integrated earth-leakage protection
- Class A earth-leakage protection class
- AdjustableEarth-leakage protection sensitity adjustment type IΔn
- Earth-leakage protection sensitivity adjustment range:
- 30 mA
- 100 mA
- 300 mA
- 500 mA
- 1 A
- 3 A
- 5 A
- Earth-leakage protection specific mode OFF using the IΔn rotary switch
- Adjustable Earth-leakage protection time delay adjustement type Δt
- Earth-leakage protection time delay adjustment range:
- 0 ms
- 60 ms
- 150 ms
- 500 ms
- 1 s
- Without zone selective interlocking ZSI
- 5 slots for electrical auxiliaries
- Local signalling:
- Flashing LED (green) for ready to operate
- LED 105 % Ir (red) for overload
- LED 90 % Ir (orange) for overload
- EN/IEC 60947 standards
- Product certifications:
- Class II overvoltage category
- Class II electrical shock protection class
- IP40 conforming to IEC 60529
- IK07 conforming to IEC 62262
MCCB NSX100 F 4P 40A 36kA With Micrologic Vigi 4