Schneider – LC1K0910M7, Kontrol AC 9A N/O 220 VAC - LC1K0910M7
Rp373.000 Sale!
Schneider Contactor LC1K0901M7 9A 3P(3NO) 220 VAC
Schneider Contactor LC1K0901M7 9A Main Specification
- Contactor product type
- TeSys K product name
- LC1K device short name
- Control device application
- Motor control contactor application
- Utilisation category:
- 3P poles description
- 3NO power pole contact composition
- Rated operational voltage:
- Power circuit: 690 V AC 50/60 Hz
- Signalling circuit: 690 V AC 50/60 Hz
- Rated operational current:
- 20 A (at <50 °C) at <= 440 V AC AC-1 for power circuit
- 9 A at <= 440 V AC AC-3 for power circuit
- 16 A (at <70 °C) at 690 V AC AC-1 for power circuit
- AC at 50/60 Hz control circuit type
- 220…230 V AC 50/60 Hz control circuit voltage
- Motor power kW:
- 2.2 kW at 220…230 V AC 50/60 Hz AC-3
- 4 kW at 380…415 V AC 50/60 Hz AC-3
- 4 kW at 440 V AC 50/60 Hz AC-3
- 4 kW at 500…600 V AC 50/60 Hz AC-3
- 4 kW at 660…690 V AC 50/60 Hz AC-3
- 2.2 kW at 400 V AC 50/60 Hz AC-4
- 4 kW at 480 V AC 50/60 Hz AC-3
- 1 NO auxiliary contact composition
- 8 kV rated impulse withstand voltage
- Overvoltage category III
- Conventional free air thermal current:
- 20 A (at 50 °C) for power circuit
- 10 A (at 50 °C) for signalling circuit
Complementary
- Irms rated making capacity:
- 110 A AC for:
- Power circuit conforming to NF C 63-110
- Power circuit conforming to IEC 60947
- Signalling circuit conforming to IEC 60947
- Rated breaking capacity:
- 110 A at 415 V conforming to IEC 60947
- 110 A at 440 V conforming to IEC 60947
- 80 A at 500 V conforming to IEC 60947
- 110 A at 220…230 V conforming to IEC 60947
- 110 A at 380…400 V conforming to IEC 60947
- 70 A at 660…690 V conforming to IEC 60947
- Associated fuse rating:
- 25 A gG at <= 440 V for power circuit
- 25 A aM for power circuit
- 10 A gG for signalling circuit conforming to IEC 60947
- 10 A gG for signalling circuit conforming to VDE 0660
- 3 mOhm – Ith 20 A 50 Hz average impedance for power circuit
- Rated insulation voltage:
- Power circuit:
- 600 V conforming to UL 508
- 690 V conforming to IEC 60947-4-1
- Signalling circuit:
- 690 V conforming to IEC 60947-4-1
- 690 V conforming to IEC 60947-5-1
- 600 V conforming to UL 508
- Power circuit:
- 600 V conforming to CSA C22.2 No 14
- 600 V conforming to CSA C22.2 No 14
Environment
- > 10 MOhm insulation resistance for signalling circuit
- 30 VA (at 20 °C) inrush power in VA
- 4.5 VA (at 20 °C) hold-in power consumption in VA
- 1.3 W heat dissipation
- Control circuit voltage limits:
- Operational: 0.8…1.15 Uc (at <50 °C)
- Drop-out: 0.2…0.75 Uc (at <50 °C)
- 3600 cyc/h maximum operating rate
- Type instantaneous 1 NO auxiliary contacts type
- <= 400 Hz signalling circuit frequency
- 5 mA minimum switching current for signalling circuit
- 17 V minimum switching voltage for signalling circuit
- Plate & Rail mounting support
- Tightening torque:
- 1.3 N.m – on screw clamp terminals with screwdriver:
- Philips No 2
- Flat Ø 6 mm
- Pozidriv No 2
- Operating time:
- 10…20 ms coil de-energisation and NO opening
- 10…20 ms coil energisation and NO closing
- 0.5 mm non overlap distance
- 10 Mcycles mechanical durability
- Electrical durability
- 0.3 Mcycles 20 A AC-1 at Ue <= 440 V
- 1.3 Mcycles 12 A AC-3 at Ue <= 440 V
- Standards:
- BS 5424
- IEC 60947
- NF C 63-110
- VDE 0660
- Product certifications:
- Protective treatment:
- TC conforming to IEC 60068
- TC conforming to DIN 50016
- -25…50 °C ambient air temperature for operation
- -50…80 °C ambient air temperature for storage
- 2000 m operating altitude without derating
- Flame retardance:
- V1 conforming to UL 94
- Requirement 2 conforming to NF F 16-101
- Requirement 2 conforming to NF F 16-102
Out of stock
Reviews
There are no reviews yet.