Schneider K1B001ALH 12A Cam ChangeOver Switch ON-OFF 2P - K1A001ALH
Rp388.600 Sale!
Schneider K1B001ALH 12A Cam ChangeOver Switch ON-OFF 2P Screw Mounting
Schneider K1B001ALH 12A Cam ChangeOver Switch Specification
- Harmony K range of product
- Complete cam switch product type
- K1 component name
- 12 A conventional free air thermal current
- Front mounting product mounting
- Multifixing mode
- With front plate 45 x 45 mm cam switch head type
- Black handle, length = 35 mm type of operator
- Without rotary handle padlocking
- With metallic legend, 2 – 0 – 1 black marking presentation of legend
- Changeover switch function
- Without return
- With Off position
- 1P
- Switching positions:
- Left: 0° – 315°
- Right: 0° – 45°
- IP degree of protection:
- IP40 conforming to IEC 529
- IP40 conforming to NF C 20-010
Complementary
- 45 ° switching angle
- 690 V rated insulation voltage (pollution degree 3) conforming to IEC 60947-1
- 10 A conventional enclosed thermal current
- Rated operational power in W:
- 10500 W AC-21, 500…660 V 3 phases conforming to IEC 947-3
- 1100 W AC-3, 230 V 3 phases conforming to IEC 947-3
- 1500 W :
- AC-23A, 230 V 3 phases conforming to IEC 947-3
- AC-3:
- 400 V 1 phase conforming to IEC 947-3
- 400 V 3 phases conforming to IEC 947-3
- 500 V 3 phases conforming to IEC 947-3
- 690 V 3 phases conforming to IEC 947-3
- 2200 W AC-23A:
- 400 V 3 phases conforming to IEC 947-3
- Â 500 V 3 phases conforming to IEC 947-3
- 690 V 3 phases conforming to IEC 947-3
- 4800 W AC-21, 230 V 3 phases conforming to IEC 947-3
- 600 W AC-3, 230 V 1 phase conforming to IEC 947-3
- 8300 W AC-21, 400 V 3 phases conforming to IEC 947-3
- Rated operational current AC:
- 1.8 A at 690 V AC-3 3 phases conforming to IEC 947-3
- 2.8 A at 500 V AC-3 3 phases conforming to IEC 947-3
- 2.8 A at 690 V AC-23A 3 phases conforming to IEC 947-3
- 3.3 A at 400 V AC-3 3 phases conforming to IEC 947-3
- 3.8 A at 500 V AC-23A 3 phases conforming to IEC 947-3
- 4.6 A at 230 V AC-3 3 phases conforming to IEC 947-3
- 4.8 A at 400 V AC-23A 3 phases conforming to IEC 947-3
- 5.6 A at 230 V AC-23A 3 phases conforming to IEC 947-3
- 1 A at 500 V AC-15 conforming to IEC 947-5-1
- 2 A at 400 V AC-15 conforming to IEC 947-5-1
- 3 A at 230 V AC-15 conforming to IEC 947-5-1
Environment
- Electrical durability:
- 1000000 cycles AC-15
- 1000000 cycles AC-21
- 500000 cycles AC-23
- 500000 cycles AC-3
- Maximum operating rate:
- 2.5 cyc/mn AC-21
- 2.5 cyc/mn AC-23
- 8.333 cyc/mn AC-15
- 2.5 cyc/mn AC-3
- 10000 A short-circuit current
- 16 A cartridge fuse, type gG short-circuit protection
- Rated impulse withstand voltage:
- 4 kV in isolating function
- 6 kV conforming to IEC 947-1
- Slow-break contact operation
- With positive opening
- Electrical connection:
- Captive screw clamp terminals flexible, clamping capacity: 2 x 1.5 mm²
- Captive screw clamp terminals solid, clamping capacity: 1 x 2.5 mm²
- 1000000 cycles mechanical durability
- Standards:
- EN 60947-3 for power circuit
- EN 60947-5-1 for control circuit
- IEC 60947-3 for power circuit
- IEC 60947-5-1 for control circuit
- CENELEC EN 50013
- Product certifications:
- CSA 240 V 3 hp 3 phases 2 pole(s)
- UL 240 V 0.33 hp 1 phase 2 pole(s)
- CSA 240 V 1 hp 1 phase
- UL 240 V 1 hp 3 phases
- TC protective treatment
- -25…55 °C ambient air temperature for operation
- -40…70 °C ambient air temperature for storage