Schneider ATV610D11N4 Inverter 11kW 3P Easy Line 380-415 V - ATV610D11N4
Rp25.258.100 Rp13.639.400 46% off! Sale!
Schneider ATV610D11N4 Inverter 11kW 3P Easy Line 380-415 V
- Easy Altivar 610 product range
- Variable speed drive product type
- Fan, pump, compressor, conveyor product specific application
- ATV610 device short name
- Standard version variant
- Asynchronous motors product destination
- Cabinet mount mounting mode
- Integrated EMC filter conforming to EN/IEC 61800-3 category C3 with 50 m
- IP20 conforming to IP degree of protection
- Forced convection cooling type
- 50…60 Hz +/-5 % supply frequency
- 3 phases network phases
- 380…460 V – 15…10 % rated supply voltage
Schneider ATV610D11N4 Inverter 11kW Main Specification
- Motor power kW:
- 11 kW for normal duty
- 7.5 kW for heavy duty
- Motor power hp:
- 15 hp for normal duty
- 10 hp for heavy duty
- Line current:
- 22 A at 380 V (normal duty)
- 19.6 A at 460 V (normal duty)
- 16.4 A at 380 V (heavy duty)
- 14.6 A at 460 V (heavy duty)
- 22Â kA prospective line Isc
- Apparent power:
- 15.6 kVA at 460 V (normal duty)
- 11.6 kVA at 460 V (heavy duty)
- Continuous output current:
- 23.5 A at 4 kHz for normal duty
- 16.5 A at 4 kHz for heavy duty
- Maximum transient current:
- 25.9 A during 60 s (normal duty)
- 24.8 A during 60 s (heavy duty)
- Asynchronous motor control profile:
- Variable torque standard
- Optimized torque mode
- Constant torque standard
- Output frequency at 0.0001…0.5 kHz
- 4 kHz nominal switching frequency
- 2 – 12 kHz adjustable switching frequency
- 16 preset speeds
- Modbus serial communication port protocol
- Slot A option card:
- Communication card, Profibus DP V1
- Digital or analog I/O extension card
- Relay output card
- Output voltage <= power supply voltage
- Motor slip compensation:
- Can be suppressed
- Adjustable
- Not available in permanent magnet motor law
- Automatic whatever the load
- Acceleration and deceleration ramps:
- Linear adjustable separately from 0.01 to 9000 s
- S, U or customized
Schneider ATV610D11N4 Inverter 11kW
- Braking to standstill By DC injection
- Protection type:
- Thermal protection: motor
- Motor phase break: motor
- Thermal protection: drive
- Overheating: drive
- Overcurrent between output phases and earth: drive
- Overload of output voltage: drive
- Short-circuit protection: drive
- Motor phase break: drive
- Line supply undervoltage: drive
- Overvoltages on the DC bus: drive
- Line supply overvoltage: drive
- Line supply phase loss: drive
- Overspeed: drive
- Break on the control circuit: drive
- Frequency resolution:
- Display unit: 0.1 Hz
- Analog input: 0.012/50 Hz
- Electrical connection:
- Control, screw terminal: 0.5…1.5 mm²
- Line side, screw terminal: 2 x 50…3 x 120 mm²
- Motor, screw terminal: 3 x 50…3 x 120 mm²
- 1 RJ45 connector (on the remote graphic terminal) for Modbus serial
- 2-wire RS 485 physical interface for Modbus serial
- RTU transmission frame for Modbus serial
- 4.8, 9.6, 19.2, 38.4 kbit/s transmission rate for Modbus serial
- No impedance polarization for Modbus serial
- 1 – 247 addresses for Modbus serial
- Slave access method
- Supply:
- External supply for digital inputs: 24 V DC (19…30 V), <1.25 mA, protection type: overload and short-circuit protection
- Internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, <10 mA, protection type: overload and short-circuit protection
- Local signalling:
- 2 LEDs for local diagnostic
- 1 LED (yellow) for embedded communication status
- 2 LEDs (dual colour) for communication module status
- 1 LED (red) for presence of voltage
- 3 analogue input number
Complementary
- Analogue input type:
- AI1, AI2, AI3 software-configurable voltage: 0 – 10 V DC, impedance: 30 kOhm, resolution 12 bits
- AI1, AI2, AI3 software-configurable current: 0 – 20 mA, impedance: 250 Ohm, resolution 12 bits
- AI2, AI3 software-configurable temperature probe or water level sensor
- 6 discrete input number
- Discrete input type:
- DI1…DI6 programmable as logic input, 24 V DC impedance: 3.5 kOhm
- DI5, DI6 programmable as pulse input: 0 – 30 kHz, 24 V DC
- Input compatibility:
- DI1 – DI6: logic input level 1 PLC conforming to EN/IEC 61131-2
- DI5, DI6: pulse input level 1 PLC conforming to IEC 65A-68
- Discrete input logic:
- Positive logic (source): DI1 – DI6 configurable logic input, < 5 V (state 0), > 11 V (state 1)
- Negative logic (sink): DI1 – DI6 configurable logic input, > 16 V (state 0), < 10 V (state 1)
- Positive logic (source): DI5, DI6 configurable pulse input, < 0.6 V (state 0), > 2.5 V (state 1)
- 2 analogue output number
- Analogue output type:
- Software-configurable current AQ1, AQ2: 0 – 20 mA, resolution 10 bits
- Software-configurable voltage AQ1, AQ2: 0 – 10 V DC impedance 470 Ohm, resolution 10 bits
- Sampling duration:
- 5 ms +/- 0.1 ms (AI1, AI2, AI3) – analog input
- 2 ms +/- 0.5 ms (DI1…DI6)configurable – discrete input
- 5 ms +/- 1 ms (DI5, DI6)configurable – pulse input
- 10 ms +/- 1 ms (AQ1, AQ2) – analog output
- Accuracy:
- +/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input
- +/- 1 % AQ1, AQ2 for a temperature variation 60 °C analog output
- Linearity error:
- AI1, AI2, AI3: +/- 0.15 % of maximum value for analog input
- AQ1, AQ2: +/- 0.2 % for analog output
Environment
- 3 relay output number
- Configurable relay output logic:
- R1 fault relay NO/NC electrical durability 100000 cycles
- R2 sequence relay NO electrical durability 100000 cycles
- R3 sequence relay NO electrical durability 100000 cycles
- Relay output refresh time (R1, R2, R3): 5 ms (+/- 0.5 ms)
- Relay output minimum switching current R1, R2, R3: 5 mA at 24 V DC9
- Maximum switching current Relay output R1, R2, R3 on:
- Resistive load, cos phi = 1: 3 A at 250 V AC
- Resistive load, cos phi = 1: 3 A at 30 V DC
- Inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC
- Inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC
- Between power and control terminals isolation
- Insulation resistance > 1 MOhm 500 V DC for 1 minute to earth
- 76 dB noise level conforming to 86/188/EEC
- 2755Â W(forced convection) power dissipation at 380 V, switching frequency 2.5 kHz
- Vertical operating position +/- 10 degree
- Electromagnetic compatibility:
- Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2
- Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3
- Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4
- 1.2/50 µs – 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5
- Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
- Vibration resistance:
- 1.5 mm peak to peak (f= 2…13 Hz) conforming to IEC 60068-2-6
- 1 gn (f= 13…200 Hz) conforming to IEC 60068-2-6
- 6 gn for 11 ms shock resistance conforming to IEC 60068-2-27
- 5…95 % relative humidity without condensation conforming to IEC 60068-2-3
Variable Speed Drive 380 – 415 V Easy Line 3P – 11kW
Out of stock
Reviews
There are no reviews yet.