MCCB NSX630H 4P 630A 70kA With Micrologic 2.3 LV432896 Schneider - C63H42D630
Rp7.040.400 Sale!
MCCB NSX630H 4P 630A 70kA With Micrologic 2.3 LV432896 Schneider
MCCB NSX630H 4P 630A Main Specification
- 690 V AC 50/60 Hz rated operational voltage
- Suitability for isolation conforming to EN/IEC 60947-2
- MCCB NSX630H 4P 630A rated ultimate short-circuit breaking capacity
- 85 kA at 240 V AC 50/60 Hz conforming to UL 508
- 65 kA at 480 V AC 50/60 Hz conforming to UL 508
- 100 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
- 35 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2
- 50 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
- 65 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
- 70 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
- 20 kA at 600 V AC 50/60 Hz conforming to UL 508
- 20 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
- Micrologic 2.3 trip unit name
- Electronic trip unit technology
- LSoI trip unit protection functions
- Toggle control type
- Fixed Circuit breaker mounting mode
Complementary
- 800 V AC 50/60 Hz rated insulation voltage
- 8 kV rated impulse withstand voltage
- Rated service short-circuit breaking capacity:
- 11 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2
- 10 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
- 100 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
- 50 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2
- 65 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
- 70 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
- 15000 cycles mechanical durability
- Electrical durability:
- 2000 cycles at 690 V In
- 6000 cycles at 690 V In/2
- 4000 cycles at 440 V In
- 8000 cycles at 440 V In/2
- Backplate mounting support
- Front upside & downside connection
- 45 mm connection pitch
- Protection type:
- L : for overload protection (long time)
- So : for short time short-circuit protection with fixed delay
- I : for instantaneous short-circuit protection
- Adjustable 9 settings Long-time pick-up adjustment type Ir (thermal protection)
- Long-time protection pick-up adjustment range from 250 to 630 A
- Fixed Long-time protection delay adjustment type tr
- 16 s at 6 x Ir long-time protection delay adjustment range
- Thermal memory 20 minutes before and after tripping
- Adjustable 9 settings Short-time protection pick-up adjustment type Isd
- 1.5…10 x Ir Short-time protection pick-up adjustment range
- Fixed Short-time protection delay adjustment type tsd
- Fixed Instantaneous protection pick-up adjustment type Ii
- 6900 A instantaneous protection pick-up adjustment range
- Without earth-leakage protection
- Without zone selective interlocking ZSI
- 6 slots for electrical auxiliaries
- Local signalling:
- Flashing LED (green) for ready to operate
- LED 105 % Ir (red) for overload
- LED 90 % Ir (orange) for overload
Environment
- EN/IEC 60947 standards
- Product certifications:
- Class II overvoltage category
- Class II electrical shock protection class
- IP40 conforming to IEC 60529
- IK07 conforming to IEC 62262
MCCB NSX100 H 4P 630A 70kA With Micrologic 22
Out of stock