MCCB NSX250H 4P 200A 70kA LV431681 Schneider - C25H6TM200
Rp7.397.100 Sale!
MCCB NSX250H 4P 200A 70kA LV431681 Schneider
MCCB NSX250H 4P 200A Main Specification
- 690 V AC 50/60 Hz rated operational voltage
- Suitability for isolation conforming to EN/IEC 60947-2
- MCCB NSX250H 4P 200A rated ultimate short-circuit breaking capacity:
- 85 kA at 240 V AC 50/60 Hz conforming to UL 508
- 65 kA at 480 V AC 50/60 Hz conforming to UL 508
- 10 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
- 100 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
- 35 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2
- 50 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
- 65 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
- 70 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
- 15 kA at 600 V AC 50/60 Hz conforming to UL 508
- TM-D trip unit name
- Thermal-magnetic trip unit technology
- LI trip unit protection functions
- Toggle control type
- Fixed Circuit breaker mounting mode
Complementary
- 800 V AC 50/60 Hz rated insulation voltage
- 8 kV rated impulse withstand voltage
- Rated service short-circuit breaking capacity:
- 10 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
- 100 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
- 35 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2
- 50 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2
- 65 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
- 70 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
- 20000 cycles mechanical durability
- Electrical durability:
- 5000 cycles at 690 V In
- 10000 cycles at 690 V In/2
- 10000 cycles at 440 V In
- 20000 cycles at 440 V In/2
- Backplate mounting support
- Front upside & downside connection
- 35 mm connection pitch
- Protection type:
- L : for overload protection (thermal)
- I : for short-circuit protection (magnetic)
- Adjustable Long-time pick-up adjustment type Ir (thermal protection)
- 0.7…1 x In long-time protection pick-up adjustment range
- Fixed Long-time protection delay adjustment type tr
- Long-time protection delay adjustment range:
- 120…400 s at 1.5 x In
- 15 s at 6 x Ir
- Adjustable Short-time protection pick-up adjustment type Isd
- 5…10 x In Short-time protection pick-up adjustment range
- Fixed Short-time protection delay adjustment type tsd
- Without earth-leakage protection
- 5 slots for electrical auxiliaries
Environment
- EN/IEC 60947 standards
- Product certifications:
- Class II overvoltage category
- Class II electrical shock protection class
- IP40 conforming to IEC 60529
- IK07 conforming to IEC 62262
- Ambient air temperature for operation at -25…70 °C
- Ambient air temperature for storage at -50…85 °C
- 0…95 % relative humidity
MCCB NSX100 H 4P 200A 70kA
Out of stock
Reviews
There are no reviews yet.