MCCB NSX100H 3P 40A 70kA C10F42D040 With Micrologic 2.2 - C10H32D040
Rp8.559.300 Sale!
MCCB NSX100H 3P 40A 70kA C10F42D040 With Micrologic 2.2 Schneider
MCCB NSX100H 3P 40A 70kA Main Specification
- 690 V AC 50/60 Hz rated operational voltage
- AC network type
- 50/60 Hz network frequency
- Suitability for isolation conforming to EN/IEC 60947-2
- MCCB NSX100H 3P 100A 70kA rated ultimate short-circuit breaking capacity:
- 10 kA at 600 V AC 50/60 Hz conforming to UL 508
- 85 kA at 240 V AC 50/60 Hz conforming to UL 508
- 65 kA at 480 V AC 50/60 Hz conforming to UL 508
- 10 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
- 100 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
- 35 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2
- 50 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
- 65 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
- 70 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
- Performance level 70 kA 415 V AC
- Micrologic 2.2 trip unit
- Electronic trip unit technology
- LSoI trip unit protection functions
- Toggle control type
- Fixed Circuit breaker mounting mode
Complementary
- 800 V AC 50/60 Hz rated insulation voltage
- 8 kV rated impulse withstand voltage
- Rated service short-circuit breaking capacity:
- 10 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
- 100 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
- 35 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2
- 50 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2
- 65 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
- 70 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
- 50000 cycles mechanical durability
- Electrical durability:
- 10000 cycles at 690 V In
- 20000 cycles at 690 V In/2
- 30000 cycles at 440 V In
- 50000 cycles at 440 V In/2
- 4.7 W power losses
- Backplate mounting support
- Front upside connection
- Front downside connection
- 35 mm connection pitch
- Protection type:
- L : for overload protection (long time)
- So : for short time short-circuit protection with fixed delay
- I : for instantaneous short-circuit protection
- Adjustable 9 settings Long-time pick-up adjustment type Ir (thermal protection)
- Long-time protection pick-up adjustment range at 18A to 40A
- Fixed Long-time protection delay adjustment type tr
- Long-time protection delay adjustment range:
- 11 s at 7.2 x Ir
- 16 s at 6 x Ir
- 400 s at 1.5 x Ir
- 20 minutes before and after tripping thermal memory
- Adjustable 9 settings Short-time protection pick-up adjustment type Isd
- 1.5…10 x Ir Short-time protection pick-up adjustment range
- Fixed Short-time protection delay adjustment type tsd
- Fixed Instantaneous protection pick-up adjustment type Ii
- 1500 A instantaneous protection pick-up adjustment range
- Without earth-leakage protection
- Without zone selective interlocking ZSI
- 5 slots for electrical auxiliaries
- Local signalling:
- Flashing LED (green) for ready to operate
- LED 105 % Ir (red) for overload
- LED 90 % Ir (orange) for overload
Environment
- EN/IEC 60947 standards
- Product certifications:
- Class II overvoltage category
- Class II electrical shock protection class
- 3 pollution degree conforming to IEC 60664-1
- IP40 from IP degree of protection conforming to IEC 60529
- IK07 from IK degree of protection conforming to IEC 62262
- Ambient air temperature for operation at -25…70 °C
- Ambient air temperature for storage at -50…85 °C
- 0…95 % relative humidity
- Operating altitude:
- 0…2000 m without derating
- 2000 m…5000 m with derating
MCCB NSX100 H 3P 40A 70kA With Micrologic 22
Out of stock
Reviews
There are no reviews yet.