Kontaktor Schneider LC1D09EHE 9 Ampere 48-130 V AC/DC - LC1D09EHE
Rp1.080.100 Rp572.500 47% off! Sale!
Kontaktor Schneider LC1D09EHE 9 Ampere 48-130 V AC/DC
Kontaktor Schneider LC1D09EHE 9 Ampere 48-130 V AC/DC Main
- Range:
- Range of product TeSys Deca
- Product or component type Contactor
- Device short name LC1D
- Contactor application:
- Resistive load
- Motor control
- Utilisation category:
- 3 Poles
- [Ue] rated operational voltage Power circuit: <= 690 V AC 25…400 Hz
- [Ie] rated operational current:
- 9 A (at <60 °C) at <= 440 V AC-3 for power circuit
- 25 A (at <60 °C) at <= 440 V AC-1 for power circuit
- 9 A (at <60 °C) at <= 440 V AC-3e for power circuit
- [Uc] control circuit voltage:
- 48…130 V AC 50/60 Hz
- 48…130 V DC
Complementary
- Motor power (kW):
- 2.2 kW at 220…230 V AC 50 Hz (AC-3)
- 4 kW at 380…400 V AC 50 Hz (AC-3)
- 4 kW at 415 V AC 50 Hz (AC-3)
- 4 kW at 440 V AC 50 Hz (AC-3)
- 5.5 kW at 500 V AC 50 Hz (AC-3)
- 5.5 kW at 660…690 V AC 50 Hz (AC-3)
- Motor power (hp):
- 0.33 hp at 115 V AC 60 Hz for 1 phase motors
- 1 hp at 230/240 V AC 60 Hz for 1 phase motors
- 2 hp at 200/208 V AC 60 Hz for 3 phases motors
- 2 hp at 230/240 V AC 60 Hz for 3 phases motors
- 5 hp at 460/480 V AC 60 Hz for 3 phases motors
- 7.5 hp at 575/600 V AC 60 Hz for 3 phases motors
- Compatibility code LC1D
- Pole contact composition 3 NO
- With Protective cover
- [Ith] conventional free air thermal current:
- 10 A (at 60 °C) for signalling circuit
- 25 A (at 60 °C) for power circuit
- Irms rated making capacity:
- 250 A at 440 V for power circuit conforming to IEC 60947
- 140 A AC for signalling circuit conforming to IEC 60947-5-1
- 250 A DC for signalling circuit conforming to IEC 60947-5-1
- Rated breaking capacity 250 A at 440 V for power circuit conforming to IEC 60947
Environment
- [Icw] rated short-time withstand current:
- 100 A – 1 s for signalling circuit
- 120 A – 500 ms for signalling circuit
- 140 A – 100 ms for signalling circuit
- 30 A 40 °C – 10 min for power circuit
- 61 A 40 °C – 1 min for power circuit
- 105 A 40 °C – 10 s for power circuit
- 210 A 40 °C – 1 s for power circuit
- Associated fuse rating:
- 10 A gG for signalling circuit conforming to IEC 60947-5-1
- 25 A gG at <= 690 V coordination type 1 for power circuit
- 20 A gG at <= 690 V coordination type 2 for power circuit
- Average impedance 2.5 mOhm – Ith 25 A 50 Hz for power circuit
- Power dissipation per pole:
- 1.56 W AC-1
- 0.2 W AC-3
- 0.2 W AC-3e
- [Ui] rated insulation voltage
- Power circuit: 690 V conforming to IEC 60947-4-1
- Signalling circuit: 690 V conforming to IEC 60947-1
Out of stock
Reviews
There are no reviews yet.