Schneider ATV630U15N4 Inverter 1.5kW 3P 380-480 V
Rp29.624.800 Rp15.404.900 48% off!
Schneider ATV630U15N4 Inverter 1.5kW 3P 380-480 V
Schneider ATV630U15N4 Inverter 1.5kW Main Specification
- Altivar Process ATV600
- Variable speed drive product type
- Process and utilities product application
- ATV630 device’s short name
- Standard version variant
- Product destination:
- Asynchronous motors
- Synchronous motors
- Integrated EMC filter with 150 m conforming to EN/IEC 61800-3 category C3
- IP degree of protection:
- IP21 conforming to IEC 61800-5-1
- IP21 conforming to IEC 60529
- 380 – 480 V rated supply voltage
- Forced convection cooling
Schneider ATV630U15N4 Inverter 1.5kW
- 50 – 60 Hz supply frequency at 5 – 5 %
- 380 – 480 V rated supply voltage at 15 – 10 %
- Motor power kW:
- 1.5 kW (normal duty)
- 0.75 kW (heavy duty)
- Motor power hp:
- 2 hp normal duty
- 1 hp heavy duty
- Line current:
- 3 A at 380 V (normal duty)
- 2.6 A at 480 V (normal duty)
- 1.7 A at 380 V (heavy duty)
- 1.5 A at 480 V (heavy duty)
- 50 kA prospective line Isc
- Apparent power:
- 2.2 kVA at 480 V (normal duty)
- 1.2 kVA at 480 V (heavy duty)
- Continuous output current:
- 4 A at 4 kHz for normal duty
- 2.2 A at 4 kHz for heavy duty
- Maximum transient current:
- 4.4 A during 60 s (normal duty)
- 3.3 A during 60 s (heavy duty)
- Asynchronous motor control profile:
- Constant torque standard
- Optimized torque mode
- Variable torque standard
- Synchronous motor control profile:
- Permanent magnet motor
- Synchronous reluctance motor
- 0.1 – 500 Hz speed drive output frequency
- 4Â kHz nominal switching frequency
- Switching frequency:
- 2 – 12 kHz with derating factor
- 4 – 12 kHz adjustable
- STO (safe torque off) SIL 3 safety
- 16 preset speeds discrete input logic
- Communication port protocol:
- Modbus TCP
- Ethernet
- Modbus serial
- Option card:
- Slot A, communication module:
- Profibus DP V1
- PROFINET
- DeviceNet
- CANopen SUB-D 9
- Modbus TCP/EtherNet/IP
- CANopen daisy chain RJ45
- CANopen screw terminals
- Ethernet IP/Modbus TCP/MD-Link
- Slot A/slot B:
- digital and analog I/O extension module
- output relay extension module
- Communication module, BACnet MS/TP
- Communication module, Ethernet Powerlink
Complementary
- Wall mount mounting mode
- 3 phases network
- Relay outputs discrete :
- R1A, R1B, R1C 250 V AC 3000 mA
- R1A, R1B, R1C 30 V DC 3000 mA
- R2A, R2C 250 V AC 5000 mA
- R2A, R2C 30 V DC 5000 mA
- R3A, R3C 250 V AC 5000 mA
- R3A, R3C 30 V DC 5000 mA
- Output voltage <= power supply voltage
- Permissible temporary current boost:
- 1.1 x In during 60 s (normal duty)
- 1.5 x In during 60 s (heavy duty)
- Motor slip compensation:
- Can be suppressed
- Not available in permanent magnet motor law
- Automatic whatever the load
- Adjustable
- Linear adjustable separately acceleration and deceleration ramps from 0.01 – 9999 s
- Physical interface:
- Transmission rate:
- 10, 100 Mbits
- 4800 bps, 9600 bps, 19200 bps, 38.4 Kbps
- Frequency resolution:
- Display unit: 0.1 Hz
- Analog input: 0.012/50 Hz
- RTU transmission frame
- Electrical connection:
- Control: removable screw terminals 0.5…1.5 mm²/AWG 20…AWG 16
- Line side: screw terminal 2 x 50…3 x 120 mm²/2 x AWG 1/0…2 x 300 kcmil
- Motor: screw terminal 2 x 50…3 x 120 mm²/2 x AWG 1/0…2 x 300 kcmil
- Connector type:
- RJ45 (on the remote graphic terminal) for Ethernet/Modbus TCP
- RJ45 (on the remote graphic terminal) for Modbus serial
- 500 kHz maximum output frequency
- 3 A maximum input current
- Motor power range AC-3:
- 0.55- 1 kW at 380 – 440 V 3 phases
- 0.55- 1 kW at 480 – 500 V 3 phases
- Wall mounted enclosure mounting
Environment
- Insulation resistance > 1 MOhm 500 V DC for 1 minute to earth
- 54.5Â dB noise level conforming to 86/188/EEC
- Power dissipation in W:
- Natural convection: 28 W at 380 V, switching frequency 4 kHz
- Forced convection: 41Â W at 380 V, switching frequency 4 kHz
- 38Â m3/h volume of cooling air
- Vertical +/- 10 degree operating position
- Maximum THDI < 48 % full load conforming to IEC 61000-3-12
- Electromagnetic compatibility:
- Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2
- Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3
- Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4
- 1.2/50 µs – 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5
- Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
- Vibration resistance:
- 1.5 mm peak to peak (f= 2…13 Hz) conforming to IEC 60068-2-6
- 1 gn (f= 13…200 Hz) conforming to IEC 60068-2-6
- Shock resistance 15 gn for 11 ms conforming to IEC 60068-2-27
- 5 – 95 % relative humidity without condensation conforming to IEC 60068-2-3
- Ambient air temperature for operation:
- -15…50 °C (without derating)
- 50…60 °C (with derating factor)
- -40…70 °C ambient air temperature for storage
- Operating altitude:
- <= 1000 m without derating
- 1000…4800 m with current derating 1 % per 100 m
- Standards:
- UL 508C
- EN/IEC 61800-3
- Environment 1 category C2 EN/IEC 61800-3
- IEC 61508
- IEC 13849-1
- Environment 2 category C3 EN/IEC 61800-3
- EN/IEC 61800-5-1
- IEC 61000-3-12
- IEC 60721-3
Out of stock
Reviews