MCCB EZC100H 2P 80A 25kA EZC100H2080 Schneider - EZC100H2080
Rp1.234.400 Rp555.500 55% off! Sale!
MCCB EZC100H 2P 80A at 40 °C, AC & DC network type 25kA EZC100H2075 Schneider:
- MCCB EZC100H 2P 80A network frequency at 50/60 Hz
- Rated insulation voltage at 690 V AC 50/60 Hz conforming to IEC 60947-2
- Rated impulse withstand voltage at 6 kV conforming to IEC 60947-2
- Rated operational voltage at 550 V AC 50/60 Hz conforming to IEC 60947-2 & 250 V DC conforming to IEC 60947-2
- Breaking capacity:
- 10 kA Icu at 125 V DC 1P conforming to IEC 60947-2
- 10 kA Icu at 250 V DC 2P conforming to IEC 60947-2
- 10 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2
- 100 kA Icu at 110…130 V AC 50/60 Hz conforming to IEC 60947-2
- 20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
- 30 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2
- 30 kA Icu at 400…415 V AC 50/60 Hz conforming to IEC 60947-2
- 50 kA Icu at 220…240 V AC 50/60 Hz conforming to IEC 60947-2
- Rated service breaking capacity:
- 15 kA at 380 V AC 50/60 Hz conforming to IEC 60947-2
- 5 kA at 125 V DC conforming to IEC 60947-2
- 5 kA at 250 V DC conforming to IEC 60947-2
- 50 kA at 110/130 V AC 50/60 Hz conforming to IEC 60947-2
- 5 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
- 2.5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2
- 7.5 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
- 25 kA at 220/230/240 V AC 50/60 Hz conforming to IEC 60947-2
- Suitability for isolation conforming to IEC 60947-2
- Category A for utilisation category
- TM-D trib unit name
- Thermal-magnetic trip unit technology
- 75 A trip unit rating at 50 °C
- Protection type:
- Overload protection
- Short-circuit protection
- 3 pollution degree conforming to IEC 60664-1 & IEC 947-1
- Toggle control type
- Fixed mounting mode
- Backplate mounting support
- Front upside connection
- Front downside connection
- 8500 cycles mechanical durability
- Category A: 1500 cycles 415 V AC 50/60 Hz of electrical durability conforming to IEC 60947-2
- 25 mm connection pitch
- Positive contact indication local signaling
- Without neutral protection setting
- without earth-leakage protection
- Standards:
- JIS C8201-2-2
- EN/IEC 60947-2
- EN/IEC 60947-1
- GB/T 14048.2
- IP20 from IP degree of protection conforming to IEC 60529
- IK07 from IK degree of protection conforming to IEC 62262
- Ambient air temperature for operation at -25 to 70 °C
- Ambient air temperature for storage at -35 to 85 °C
Out of stock
Reviews
There are no reviews yet.