MCB iC60H 1P 25A D Curve Schneider A9F85125 10kA
Rp517.300 Rp248.300 52% off!
MCB iC60H 1P 25A D Curve Schneider A9F85125 10kA (IEC 60898-1) & 15 kA (IEC 60947-2) with :
- AC & DC Network type
- Thermal-magnetic trip unit
- D curve
- MCB iC60H 1P 25A breaking capacity :
- 10000 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1
- 15 kA Icu at 220…240 V AC 50/60 Hz conforming to EN/IEC 60947-2
- 42 kA Icu at 12…60 V AC 50/60 Hz conforming to EN/IEC 60947-2
- 30 kA Icu at 100…133 V AC 50/60 Hz conforming to EN/IEC 60947-2
- 15 kA Icu at 60…72 V DC conforming to EN/IEC 60947-2
- 20 kA Icu at 12…60 V DC conforming to EN/IEC 60947-2
- Utilisation category :
- Category A conforming to EN 60947-2
- Category A conforming to IEC 60947-2
- Suitability for isolation conforming to:
- EN 60898-1
- EN 60947-2
- IEC 60898-1
- IEC 60947-2
- Standards :
- EN 60947-2
- IEC 60898-1
- EN 60898-1
- IEC 60947-2
- 50/60 Hz network frequency
- 12 x In +/- 20 % magnetic tripping limit
- Rated service breaking capacity :
- 21 kA 50 % conforming to EN 60947-2 – 12…60 V AC 50/60 Hz
- 7.5 kA 50 % conforming to EN 60947-2 – 220…240 V AC 50/60 Hz
- 21 kA 50 % conforming to IEC 60947-2 – 12…60 V AC 50/60 Hz
- 7.5 kA 50 % conforming to IEC 60947-2 – 220…240 V AC 50/60 Hz
- 7500 A 75 % conforming to EN 60898-1 – 230 V AC 50/60 Hz
- 7500 A 75 % conforming to IEC 60898-1 – 230 V AC 50/60 Hz
- 15 kA 50 % conforming to IEC 60947-2 – 100…133 V AC 50/60 Hz
- 15 kA 50 % conforming to EN 60947-2 – 100…133 V AC 50/60 Hz
- 15 kA 100 % conforming to EN 60947-2 – 72 V DC
- 15 kA 100 % conforming to IEC 60947-2 – 72 V DC
- 20 kA 100 % conforming to EN 60947-2 – 12…60 V DC
- 20 kA 100 % conforming to IEC 60947-2 – 12…60 V DC
- Limitation class:
- 3 conforming to EN 60898-1
- 3 conforming to IEC 60898-1
- Rated insulation voltage :
- 500 V AC 50/60 Hz conforming to EN 60947-2
- 500 V AC 50/60 Hz conforming to IEC 60947-2
- Rated impulse withstand voltage :
- 6 kV conforming to EN 60947-2
- 6 kV conforming to IEC 60947-2
- Toggle control type
- Trip indicator local signalling
- Fixed mounting mode
- DIN rail mounting support
- Top or bottom comb busbar and distribution block compatibility
- 20000 cycles of mechanical durability
- 10000 cycles of electrical durability
- Connections – terminals :
- Single terminal (top or bottom) 1…35 mm² rigid
- Single terminal (top or bottom) 1…25 mm² flexible
- 14 mm for top or bottom connection wire stripping length
- 3.5 N.m top or bottom tightening torque
- Without earth-leakage protection