Autonics AT8N Timer AC/DC 100-240VAC, 24-240VDC - AU-AT8N
Rp246.500 Rp197.200 20% off! Sale!
Autonics Timer AT8N AC/DC 100-240VAC, 24-240VDC
Autonics Timer AT8N AC/DC 100-240VAC, 24-240VDC.
- Metode operasi: timer setting
- Operasi output : power on delay, flicker, interval
- Waktu operasi : power on start
- Terminal : 8-pin plug
- Catu daya : 100-240VAC, 24-240VDC
- Output kontrol : time limit SPDT
Datasheet
- Metode operasi Pengaturan waktu
- Operasi output
- POWER ON DELAY
- FLICKER
- INTERVAL
- Waktu operasi POWER ON START
- 8-pin plug Terminal
- Catu daya 100-240VAC~, 24-240VDC
- Kisaran pengaturan : 0.05 to 0.5 sec, 0.1 to 1 sec, 0.5 to 5 sec, 1 to 10 sec, 0.05 to 0.5 min, 0.1 to 1 min, 0.5 to 5 min, 1 to 10 min, 0.05 to 0.5 hour, 0.1 to 1 hour, 0.5 to 5 hour, 1 to 10 hour, 5 to 50 hour, 10 to 100 hour
- Output kontrol
- Time-limit DPDT (1c): 2
- Instantaneous SPDT (1c): 1+
- Time-limit SPDT (1c): 1 depending on output operation mode
- Bracket accessories
- Lingkungan kadar suhu -10 hingga 55℃, ruang tertutup: -25 hingga 65℃
- Lingkungan kadar kelembaban 35 hingga 85%RH
- Berat Kurang lebih 134.12 gram (kurang lebih 86.71 gram)
Glossary and Functions
- Pulse, An wave that has repetitive and temporal changes of its level.
- Count, Counting the number of pulses.
- Miss count, A state that number of pulses and counted is not matched.
- CPS: Count Per Second, Unit of counts per second that express counting speed
- Duty ratio, It is the ratio of the ON time and OFF time of the counting input signal. The maximum counting speed of each counter is the counting speed when the duty ratio is 1:1.
- Maximum counting speed, The maximum counting speed at which the output section of the counter operates accurately without miscounting when input signal with duty ratio is 1:1. The counting speed is expressed in units of counts per second (CPS).
- Zero blanking, A function that removes unnecessary “zero” on display so that users do not have to be confused when reading display.
- E.g.) When 123 is being displayed
- Display with zero blanking function applied: 123
- Display without zero blanking function: 0123
- Memory protection, A function that restores data counted until right before the main power is cut off and shows it on the display when having power source back.
- Reset, To restore the counting, display and output sections of the counter, to their initial states.
- Manual reset: Press the Reset button on the front of the counter to return to the initial state.
- Power reset: To reset the counter by cutting off the operating supply voltage.
- External reset: To reset the counter by applying a specific signal to the reset input signal terminal.
- Automatic reset: To reset the counter automatically with a signal generated from inside the counter.
- Reset signal width: Min. reset signal width to reset by power off or by applying external (manual) reset signal.
Low stock