Schaneider LTMR100PBD Motor Management System 5 – 100A TeSys T - LTMR100PBD
Rp24.890.700 Sale!
Schaneider LTMR100PBD Motor Management System 5 – 100A TeSys T
Schaneider LTMR100PBD Ethernet Motor Management System 5 – 100A Main Specification
- TeSys range
- TeSys T product name
- LTMR device short name
- Motor controller product type
- Equipment monitoring and control device application
- 5 – 100A measurement current
- 24 V DC rated supply voltage
- 56…127 mA current consumption
- 20.4…26.24 V DC supply voltage limits
- Modbus TCP/EtherNet/IP communication port protocol
- Bus type:
- Profibus DP polarised 2-wire RS485 interface, addressing 1…125, transmission rate 9.6 kbit/s…12 Mbit/s, SUB-D 9 with 2 shielded twisted pairs, type A
- Profibus DP polarised 2-wire RS485 interface, addressing 1…125, transmission rate 9.6 kbit/s…12 Mbit/s, terminal block with 2 shielded twisted pairs, type A
- Rated insulation voltage 690 V conforming to:
- EN/IEC 60947-1
- CSA C22.2 No 14
- UL 508
- Rated impulse withstand voltage:
- 6 kV current or voltage measurement circuit conforming to EN/IEC 60947-4-1
- 0.8 kV communication circuit conforming to EN/IEC 60947-4-1
- 0.8 kV supply, inputs and outputs conforming to EN/IEC 60947-4-1
- 100 kA short-circuit withstand conforming to EN/IEC 60947-4-1
- Associated fuse rating:
- 4 A gG for output
- 0.5 A gG for control circuit
- Protection type:
- Load fluctuation
- Reverse polarity protection
- Locked rotor
- Thermal protection
- Overload (long time)
- Overload
- Power factor variation
- Earth-leakage protection
- Thermal overload protection
- Phase unbalance
- Phase failure
Complementary
- Network and machine diagnosis type:
- Trip context information
- Event recording
- Waiting time after overload tripping
- Running hours counter/operating time
- Remaining operating time before overload tripping
- Fault recording
- Motor control command recording
- Trip history information
- Phase fault and earth fault trip counters
- Starting current and time
- 6 logic input number
- 7 mA input current
- Logic input current state 0 guaranteed: < 5 V and <= 15 mA for 5 ms
- Logic input current state 1 guaranteed: < 15 V and 2…15 mA for 15 ms
- 2 Hz maximum output switching frequency
- Load current:
- 5 A at 250 V AC for logic output
- 5 A at 30 V DC for logic output
- Permissible power:
- 480 VA (AC-15), Ie = 2 A, 500000 cycles (output)
- 30 W (DC-13), Ie = 1.25 A, 500000 cycles (output)
- 1800 cyc/h maximum operating rate
- Contacts type and composition:
- 1 NO + 1 NC fault signal
- 3 NO
- Metering type:
- Imbalance current
- Temperature
- Average current Iavg
- Phase current I1, I2, I3 RMS
- Earth-fault current
- Measurement accuracy:
- 5…15 % earth fault current internal measurement
- 1 % voltage (100…830 V)
- 3 % power factor
- 5 % earth fault current external measurement
- +/- 30 min/year internal clock
- 0,02 temperature
- 5 % active and reactive power
- 0,02 current
- Overvoltage category III
- 5.08 mm connection pitch
- Control circuit: connector 1 cable(s):
- 0.25…2.5 mm² (AWG 24…AWG 14) flexible with cable end
- 0.2…2.5 mm² (AWG 24…AWG 14) flexible without cable end
- 0.25…2.5 mm² (AWG 24…AWG 14) flexible without cable end
- 0.2…2.5 mm² (AWG 24…AWG 14) solid without cable end
- Control circuit: connector 2 cable(s):
- 0.2…1 mm² (AWG 24…AWG 14) flexible with cable end
- 0.2…1.5 mm² (AWG 24…AWG 14) flexible without cable end
- 0.5…1.5 mm² (AWG 24…AWG 14) flexible without cable end
- 0.2…1 mm² (AWG 24…AWG 14) solid without cable end
- Control circuit tightening torque at 0.5…0.6 N.m flat screwdriver 3 mm
Environment
- Electromagnetic compatibility:
- Electrostatic discharge, 3, 8 kV air, 6 kV contact, conforming to EN/IEC 61000-4-2
- Radiated RF fields, 3, 10 V/m, conforming to EN/IEC 61000-4-3
- Fast transients immunity test (other circuits), level 3, 2 kV, conforming to EN/IEC 61000-4-4
- Fast transients immunity test (on supply and relay outputs), level 4, 4 kV, conforming to EN/IEC 61000-4-4
- Voltage dips and interruptions immunity test, 70 %, 500 ms, conforming to EN/IEC 61000-4-11
- Conducted RF disturbances, 10 V, conforming to EN/IEC 61000-4-6
- Temperature sensor: surges (serial mode), 0.5 kV, conforming to EN/IEC 61000-4-5
- Temperature sensor: surges (common mode), 1 kV, conforming to EN/IEC 61000-4-5
- Control circuit: surges (serial mode), 1 kV, conforming to EN/IEC 61000-4-5
- Control circuit: surges (common mode), 1 kV, conforming to EN/IEC 61000-4-5
- Communication: surges (common mode), 2 kV, conforming to EN/IEC 61000-4-5
- Relay outputs and supply: surges (serial mode), 2 kV, conforming to EN/IEC 61000-4-5
- Relay outputs and supply: surges (common mode), 4 kV, conforming to EN/IEC 61000-4-5
- Web server services
- Standards:
- CSA C22.2 No 14
- EN 60947-4-1
- IACS E10
- IEC 60947-4-1
- UL 508
- Product certifications:
- CCC
- BV
- KERI
- C-Tick
- GL
- ATEX
- RINA
- CSA
- EAC
- UL
- NOM
- DNV
- LROS (Lloyds register of shipping)
- ABS
- RMRoS
- Protective treatment:
- 12 x 24 hour cycles conforming to EN/IEC 60068-2-30
- 48 h conforming to EN/IEC 60070-2-11
- TH conforming to EN/IEC 60068
- Fire resistance:
- 650 °C conforming to EN/IEC 60695-2-12
- 960 °C conforming to UL 94
- -20…60 °C ambient air temperature for operation
- -40…80 °C ambient air temperature for storage
- Operating altitude <= 2000 m without derating
- Mechanical robustness:
- Vibrations mounted on symmetrical rail: 1 Gn, 5…300 Hz conforming to EN/IEC 60068-2-6
- Vibrations plate mounted: 4 Gn, 5…300 Hz conforming to EN/IEC 60068-2-6
- Shocks half sine wave acceleration: 15 Gn for 11 ms conforming to EN/IEC 60068-2-27
- IP20 from IP degree of protection