Main Specification
- Harmony XALD range of product
- Complete control station product type
- XALD device short name
- For XB5 Ø 22 mm control and signalling units product destination
- Start function control station application
- Light grey (RAL 7035) colour of base of enclosure
- Dark grey (RAL 7016) colour of cover
- Polycarbonate material
- 1 mushroom head push-button operator profile
- Red ”ARRET” 1 NC operators description
- 1 mushroom head Ø 40 mm push-button, red 1 NC ARRET marking control station composition
- Marking on legend holder marking location
- Slow-break contact operation
Complementary
- Cable entry:
- 1 knock-out for cable entry, clamping capacity: 14 mm
- 2 knock-outs for Pg 13 cable gland and ISO M20, clamping capacity: 12 mm
- 0.135 kg net weight
- 7000000 Pa at 55 °C, distance : 0.1 m resistance to high pressure washer
- Colour of marking:
- White marking when green, red or black caps
- Black marking when white caps
- Without positive opening
- Operating travel:
- 2.6 mm (NC changing electrical state)
- 4.3 mm (total travel)
- 3.8 N NC changing electrical state operating force
- 10000000 cycles mechanical durability
- Connections – terminals:
- Screw clamp terminals, <= 2 x 1.5 mm² with cable end conforming to EN/IEC 60947-1
- Screw clamp terminals, >= 1 x 0.22 mm² without cable end conforming to EN/IEC 60947-1
- 0.8…1.2 N.m conforming to EN/IEC 60947-1 tightening torque
- Shape of screw head:
- Cross compatible with Philips no 1 screwdriver
- Cross compatible with pozidriv No 1 screwdriver
- Slotted compatible with flat Ø 4 mm screwdriver
- Slotted compatible with flat Ø 5.5 mm screwdriver
Environment
- Silver alloy (Ag/Ni) contacts material
- 10 A cartridge fuse type gG short-circuit protection conforming to EN/IEC 60947-5-1
- 10 A conventional free air thermal current conforming to EN/IEC 60947-5-1
- 600 V (pollution degree 3) rated insulation voltage conforming to EN/IEC 60947-1
- 6 kV rated impulse withstand voltage conforming to EN/IEC 60947-1
- Rated operational current:
- 6 A at 120 V, AC-15, A600 conforming to EN/IEC 60947-5-1
- 3 A at 240 V, AC-15, A600 conforming to EN/IEC 60947-5-1
- 1.2 A at 600 V, AC-15, A600 conforming to EN/IEC 60947-5-1
- 0.55 A at 125 V, DC-13, Q600 conforming to EN/IEC 60947-5-1
- 0.27 A at 250 V, DC-13, Q600 conforming to EN/IEC 60947-5-1
- 0.1 A at 600 V, DC-13, Q600 conforming to EN/IEC 60947-5-1
- Electrical durability:
- 1000000 cycles, AC-15, 2 A at 230 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C
- 1000000 cycles, AC-15, 3 A at 120 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C
- 1000000 cycles, AC-15, 4 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C
- 1000000 cycles, DC-13, 0.2 A at 110 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C
- 1000000 cycles, DC-13, 0.5 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C
- Electrical reliability:
- Λ < 10exp(-6) at 5 V and 1 mA conforming to EN/IEC 60947-5-4
- Λ < 10exp(-8) at 17 V and 5 mA conforming to EN/IEC 60947-5-4
- TH protective treatment
- -40…70 °C ambient air temperature for storage
- -40…70 °C ambient air temperature for operation
- Overvoltage category Class II conforming to IEC 60536
- IP degree of protection:
- IP66 conforming to IEC 60529
- IP67
- IP69
- IP69K
- Degree of protection of NEMA :
- NEMA 13
- NEMA 4X
- IK03 conforming to EN 50102
- Standards:
- EN/IEC 60947-5-4
- EN/IEC 60947-5-1
- JIS C8201-5-1
- UL 508
- EN/IEC 60947-5-5
- EN/IEC 60947-1
- CSA C22.2 No 14
- JIS C8201-1
- 5 gn (f= 12…500 Hz) vibration resistance conforming to IEC 60068-2-6
- Shock resistance:
- 30 gn (duration = 18 ms) for half sine wave acceleration conforming to IEC 60068-2-27
- 50 gn (duration = 11 ms) for half sine wave acceleration conforming to IEC 60068-2-27
Out of stock
Schneider XALD164 Control Station With 1 Red Mushroom Push Button 40mm & Legend Holder Marked ARRET
Schneider XALD164 Control Station With 1 Red Mushroom Push Button
Be the first to review “Schneider XALD164 Control Station With 1 Red Mushroom Push Button” Cancel reply
You must be logged in to post a review.
Recently Viewed Products
Related products

Most Complete Product Range
We have thousands of products in our shop to help fulfil your need.

Free Shipping & Return
We offer free shipping on selected cities in East Java, Terms & Condition apply.

Secure Database & Payment
Your information is transmitted in a very safe way.

Supportive Customer Service
Say hello to us at +6282223332830
Contact Us
Head Quarter
031 59178887031 59173980
WA : +62 822 2333 2830
Showroom Surabaya
031 99909120WA : +62 822 2888 2830
Showroom Pandaan
0343 4857758WA : +62 889 7378 3384
About Us
Ruko Galaxi Bumi Permai J-1 No. 23, Surabaya
© 2019 – 2025 PT. Anugerah Tama Sejati
The Taman Dayu, Cluster Palazio Boulevard, J-1No. 06,
Pandaan, Pasuruan
© 2019 – 2025 PT. Anugerah Tama Sejati
Reviews
There are no reviews yet.